Copeland compressor nomenclature pdf. and European Safety Standards.


Copeland compressor nomenclature pdf Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Pg. 5x 10. 5 HP . Hazards 3 Flammable Refrigerant Hazards 4. 5 - 10. Important Safety Information 3 . Display LEDs clearly indicate the operational status of the compressor and whether or not there are any active compressor warnings, trips or lockouts Cross Reference: Trane-SF-Danfoss-Copeland *SF Compressors available April 2016. Also for: Copeland fmv9a-zb 58-tfm, Copeland fmv9a-zb 66-tfm, Copeland fmv6a-zb 66-tfm, Nomenclature & BOM 3 Application Envelope 4-5 R22 4 R404A/R507 & R134a 5 Application Guide 1. Also for: Copeland 4ma-22x, Copeland 4ml We have 1 Emerson Copeland D6D Series Compressor manual available for free PDF download: Application Manuallines Emerson Copeland D6D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. Compressor Family Series CR CR 22 K 6 M P F 1 131 BOM Data 220-1 198-264 - - Z 230-1 180-260 - - 1 400-3 340-460 - - 5 400-3 360-460 - - 6 400-3 342-462 - - M 400-3 342-462 - - D 208/230-1 197-253 V CR Series Compressor Nomenclature * Used for nomenclature purpose DWM Copeland™ compressors are suitable for a wide range of applications either in the form of single compressors, condensing units or as multi-compressor equipment. The next generation Discus lineup has been Copeland certified compressors working hard to keep their systems safe and efficient, today. Powering today’s 13+ SEER applications, the next generation of Copeland scroll technology 5 to 12 Ton ZP*K3, ZP*KC, and ZP*KW R-410A Copeland Scroll Compressors for Air Conditioning BULLETIN NO: AE4-1365 R6 Safety Important Safety Information 3 Responsibilities, Qualifications and Training 3 Terminal Venting and Other Pressurized System Hazards 3 Flammable Refrigerant Hazards 4 Electrical Hazards 4 Hot Surface and Fire Hazards 4 Lifting Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. C7. AE4-1387 R7 AE4-1387 R7 March 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll™ Compressors 1. An example would be the ZP233KZE-TED, which has 233,000 Btu/hr (68. Particular emphasis has been placed on the user's safety. These instructions should be retained throughout the lifetime of the compressor. nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. Scroll wear in The scroll involutes of Copeland scroll compressor wear in, rather than wear out. Application Engineering Europe 3/18 2 BOM number The BOM (Bill of Material) indication contains three digits, either numbers or letters, and can be found at the end of the scroll compressor nomenclature. 83 4M CO 2 Compressor Parts . An example would be %PDF-1. With as much as a 200 watt reduction in power consumption, systems equipped with Copeland Scroll two-stage compressors are ideal COPELAND 3DSDR17ME-TFD air compressor pdf manual download. Copeland Scroll ZR KC Series air compressor pdf manual download. Nomenclature The model numbers of the Copeland Discus Digital™ compressors with CoreSense™ Technology High efficiency Copeland Discus Digital ™ compressors with CoreSense technology offer digital modulation as the most precise method of capacity control to eliminate traditional compressor cycling modulation problems like uneven cooling and reduced compressor life. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. 10 Nomenclature details added. 5” (same as previous Copeland Scroll models) For complete product details and additional information, visit EmersonClimate. Note that the same compressor will have Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 . 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. Transcritical Copeland scroll compressors have earned a reputation for proven performance – performance that delivers quality, reliability and customer satisfaction. Combin- ing world class effi ciency and reliability, Discus is the compres-sor of choice to meet your refrigeration needs. Note that the same Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. one protector, (line break). Random tests of competitors’ rebuilt compressors found that capacities ran as low as 56 percent of specification. 84 6D/R/T - Semi-Hermetic Compressors. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. 13 Pressure Relief Valve drawing changed. 11 OMC CO2 Specification Chart added Pg. See Figure 1 (page 11). 3-4. Printed in the U. 5x 22. Voltage Tonnage Trane OEM COM # *SF COM # Danfoss COM # Copeland COM #s. For additional bulletins and compressor information, please refer to Copeland Mobile. 3PA3R85KL- TFD-C. Connection. A wide spectrum of operating ranges and hundreds of available models make these compressors an optimal selection for every refrigeration need. 11 Drawing of Subcritical DX System changed. com +86 15238366463 advantage of the Copeland Scroll compressor's axial compliance. 5 2 2. Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. Operating Envelope There are several refrigerants that have been approved for use with the 1. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. 4. 5x 7. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. CoreSense Protection is noted by a ' C ' in the build of materials, e. Bristol Compressors International, Inc. These compressors are designed for use with R410A (ZP) 1. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. If any type of discharge line shut-off valve is used, the high pressure control must be installed between the compressor discharge fitting and the valve. Copeland Stream 4M* and 6M* compressors are intended for installation in systems in accordance with the following directives and regulations: Compressor Compressor 2 x maroon 2 x maroon 2 x blue 2 x maroon 2 x maroon 2 x green 2 x blue 2 x blue The R22 low temperature Discus condensing units are including the Demand Cooling (D. f internal inherent Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 40. Safety icons are explained below and safety instructions applicable to the products in this bulletin are grouped on Page 3. 0kW) cooling capacity at the AHRI high temperature air conditioning rating point. These compressors are intended only for refrigeration and air conditioning use and should not be used in any other applications. The previous generation will be phased out by the end of 2010. The ZR*KC and ZP*KC scrolls outlined in this bulletin range in size from 84,000 to 190,000 Btu/hr (24. Nomenclature The model numbers of Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 5 - 17 Offset Mounting Rail Horizontal/Vertical Mount Ensure the compressors are installed on a solid level base. Therefore the information in this manual relates to all semi-hermetic Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data Compressor nominal 60 Hz capacity, rating condition to two significant digits. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. The following Application Engineering bulletins should be consulted for non-modulating scroll application guidelines: AE4-1331 ZPD34-ZPD54K5 AE4-1365 ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC. 7 %âãÏÓ 8114 0 obj >stream hÞ´›Û®d¹qm eÿA%ɸ €!@ð çÀ°p à‡B?”[u¤†»«„r °ÿÞäÊ +¹ ßü qt /¹¸f ¹'ƒ]Þ o]ßz ëöÖô±È«½ Ç[}Ìÿ, òV×ç­ÌÿUÕ·&mþOúü'y¼y³úV|¶*ÅÄßj5{+bÖÞê¨óÓÞ‡Ìú>ÿ»ªù[ uÖÒÚê›\ߪÕ"ob}Ì ½è›ÎÊo­y­oª¶¾TQy3 êü®ÖÛlPÕë }}ªÝíÍm6 + Copeland_discus_model_chart. Nomenclature The Copeland Scroll compressor model numbers 2. pdf), Text File (. 2 °C) to avoid oil dilution in the compressor but low return gas temperature enough to keep the compressor discharge temperature below 250°F (121. More than 300 models are available including medium temperature R-404A models for food service, ice machines, soft Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 44. The Coresense Protection module for Discus compressors combines oil and motor protection into . 98 6R 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 801 = std. Please refer to product literature for specific model number details. 4 to 53. The unique Discus valve design provides improved effi ciency at CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1/6 1/2 KCJ 1 to 1 ¼ HP R22, R404A KCJ to 1HP R22, R134a, R404A ¼ KCN to HP R404A 1/6 /2 R134a, CRKQ 4 to 6HP R22M CRK6/KCM 1. Safety. replacement compressor and For additional information, please refer to Copeland Mobile. . Copeland Scroll two-stage compressors lead the industry with a greater level of comfort and energy effi ciency, saving up to 25 percent on energy costs as compared to conventional HVAC systems. This bulletin describes the operating characteristics, design features, and application requirements for these models. An example would be the ZP90KCE-TFD, which has 90,500 But/hr (26. Compressor Internal Protections 7-8 3. TI_Scroll_BOM_EN_Rev00 3/22 2 BOM number The BOM (Bill of Material) indication contains three digits, either numbers or letters, and can be found at the end of the scroll compressor nomenclature. COPELAND F Series heat pump pdf manual download. Code 208/230-3 200-3 C 460-3 380/420-3 D 575 Copeland™ compressor Copeland Parts and accessories ™ compressor – Parts and accessories 2014DS-78 R2_cover. This new lineup will be * Units with a compressor RLA under 6A do not require pressure controls for UL listing. Responsibilities, Qualifications and Training 3. 89 6D Delta Reed Models . All Copeland Scroll compressors are designed so that the compression elements can separate axially a few thousands of an inch. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z Copeland Scroll compressors brochures or Copeland™ Products Selection Software. To avoid abnormally high operating pressures, a high pressure control must be used in all applications. FROM: CopelandTM Marketing – Air Conditioning SUBJECT: Introducing a new generation of 6-40T Commercial Copeland ScrollTM Compressors optimized for R410A, R32 and R454B Introduction Emerson is pleased to introduce a new generation of 6-40T Commercial scroll compressors, with the first models launching in February 2020. F Extra Low Temp. txt) or view presentation slides online. 98 MB Copeland Scroll™compressors are manufactured according to the latest U. replacement compressor and component. Therefore the information in this manual relates to all semi-hermetic Compressor cycling problem solved with Copeland Discus Digital™ compressors: English: PDF: 471 kB: Download: Hypermarket Achieves Efficiency Goals with Digital Modulation: English: PDF: 582 kB: Download: Name Languages Type Size Link; Improved Refrigeration Operation for Price Chopper Grocery Stores: English, Français: PDF: 113 kB: Download: Supermarket Improves Breakthrough efficiency Emerson’s Copeland variable speed scroll compressors are designed to deliver maximum cooling and heating efficiency when you need it most. 5 3 3. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". The Operating principles of the Copeland Scroll compressor are described in Figure 7. The models include a number of features outlined in the matrix below. For actual compressor K40-KV-A-PDS-25 - 2 - 27/04/2023 NOMENCLATURE KVS 040 M 8 - H T4 B - A - C KeepRite Vertical Air Flow Condensing Unit KVS = Single Compressor / Single Condenser KVD = Dual Compressor / Dual Condenser Nomenclature • Semi-Hermetic Condensing Units X X X X - X X X X - X X X - X X X Refrigerant R404A/507 J/4 R134a T/2 R12 B/7 R22 3/M/L/C Multiple F R22/407C G R22 9 R134a/404A/22 N R134a/404A P R404A/22 8 Temperature Application Description Code High Temperature H Medium Temperature M Low Temperature L Extended Medium Temp. The scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 53,500 Btu/hr (4. Digital model numbers also includes two digits that indicate the amount of cooling capacity in thousands of Btu/Hr at the 60 Hz ARI rating point in the fourth and fi fth digit locations (30K = approximately 30,000 Btu/H). Application Engineering . Contents . Click to view View and Download Emerson Copeland Scroll ZR KC Series bulletin online. 5 to 5 Ton ZP*K7 R-410A Copeland Scroll Compressors. United States English Compressor nominal capacity at rating con-dition to two or three significant digits. 3- 4. Delete from my manuals. is not affiliated with Trane International, Inc. 4M - CO 2 Semi-Hermetic Compressors . one module, as well as offering optional protection against high discharge temperature and communication Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. 7 to 15 TonCompressors. 2011DS-4 F-Line R1 (11/15)1 Emerson Climate Technologies Bill of Materals Matrix BOM Options UL Flare (Obsolete) Sweat Receiver W/ Valve Suction Valve Liquid Base Valve Fan Guard End Covers Conduit Power Cord Accumulator† Fan Cycling Pressure Controls Filter Drier Moisture Indicator Solenoid Valve Crankcase Heater Head Pressure Control Valve Water Valve 1. use with contactor. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. Number –230 indicates a standard compressor B/M and model number. You Nomenclature The HFC/HFO compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions. Model Variation A number or a letter, assigned to indicate different model types within any one family series. They may be put to service only if they have been installed in these systems according to Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. AE4-1311 R8 2 2013 Emerson Climate Technologies, Inc. Particular emphasis has been placed on the user’s safety. The capacity control kit supplied by DWM Copeland will reduce the refrigeration capacity along with a similar proportional reduction in Power Input. The centre letter "F" (eg, TFD) stands for inherent motor protector (Klixon) which is embedded in the stator head and interrupts the power supply of the windings internally at high current or high Mounting pattern 7. The HCFC models still refer to the nominal horsepower, (hp). Scribd is the world's largest social reading and publishing site. 44r3) represents the compressor family series and indicates tandem compressor digit 3 displacement and valve plate a letter only, arbitrarily assigned for each different displacement valve plate LG Compressor Nomenclature & Serial Number . For actual compressor ZB compressors are approved for R404A, R507, R22, R134a, R407F, R448A and R449A refrigerants. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. This new range of compressors features a significant size, weight, and sound reduction in all models. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1 /6 1 2 KCJ 1 to 1 ¼ HP R22, R404A KCJ to 1HP R22, R134a, R404A ¼ KCN to HP R404A 1/6 1/2 R134a, CRKQM 4 to 6HP R22 CRK6/KCM 1. 3 to 3 HP, R22, R134a, R404A 1/ 2 Split AC Cold Room Display Cabinet Water Most Common Regions. The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. Add to my manuals. Contact Now. Capacities are at 50/115 operating conditions. Compressors in this size range include a number of Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. 2 3 Table of Contents Content Page Centers for World-Class Manufacturing Excellence 4 Condensing Unit Overview 6 • ZX Family Condensing Units 10 • KHZ Condensing Units 16 • F-Series Scroll Condensing Unit 20 • Semi-Hermetic Condensing Units 22 •M ulti-Compressor Racks 24 • Copeland™ Discus™ compressors deliver best in class performance Copeland Discus compressors have been the unquestioned leader in commercial refrigeration for over 30 years. C. 6 to 55. 5 21. 4 Mounting parts Four vibration absorber grommets are supplied with each compressor. Terminal Venting and Other Pressurized System. The ZPD34-ZPD54K5, ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE, and ZRD36-81KC compressors described in this bulletin use a lift piston Copeland Scroll™ Outdoor Refrigeration Unit Medium and low temperature applications Convenience Store • Restaurant R-22, 134a, 404A/507A, 407C/A, 448A/449A • ¾ - 6 HP. 0 115 1 60 230 1 60 208-230 1 60 9. 5 HP Safety Copeland Compressors and Condensing Units for Refrigeration Applications. 4 Robustness and reliability • The Copeland Compliant Scroll design is tolerant to stresses caused by liquid slugging, flooded starts and debris commonly found in refrigeration compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air Copeland™ semi-hermetic compressors are manufactured according to the latest European safety standards. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Copeland scroll compressors are manufactured according to the latest relevant European safety standards. 120 volt control. Semi-Hermetic Compressor Stream for refrigeration applications. 5T Observe all applicable standards and codes for installing, servicing, and maintaining electrical and refrigeration equipment. URL of this page: HTML Link: Bookmark this page. Each compressor has a terminal cover or molded plug that covers electrical connections. So unlike in other compressor technologies among similar categories, there is no constant degradation of performance with time due to wear out. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. Hot Surface and Fire Hazards 4. The series has a wide application envelope 2. 14 Operating Envelop changed. 230-3 6 COM08294 SFCOM072-23020C COM11175 7 COM08288 SFCOM084-23020C COM10205 COM11176 COM11303 8 COM08305 SFCOM096-23020C COM11158 COM11445 COM08725 Compressor family Z = Copeland Scroll Capacity multiplier K = x 1000 M = x 10000 BOM number. 61 MOTORS 621–659 HONEYWELL 537–583 JOHNSON/RANCO 479–535 ACCUMULATORS/ RECEIVERS 260–279 SPORLAN 169–248 OIL/RECOVERY/ FITTINGS 123–159 BLANCHARD/BOHN COILS Hermetic compressors have been developed for the 1/3 hp to 1 ¼ hp refrigeration applications. 5 6. These compressors are intended for installation in systems according to the Machinery Directive MD 2006/42/EC. Application Range Compressor Family Series Either a number or a letter established for each product model. Other performance data available to the system Copeland Discus™ compressors combines oil and motor protection into one module, as well as offers optional protection against high discharge temperature and communication compatibility with Modbus communication devices. The rotor shaft axis is in the vertical plane. Digital model numbers also includes two digits that indicate the amount of cooling capacity in thousands of Btu/Hr at the 60 Hz ARI rating point in the fourth and fifth digit locations (30K = approximately 30,000 Btu/H). 8 x 8. 56) MFD Volts Height (inch) Suction_ID (inch) Suction_H (inch) Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 44. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. 44 x 9. and European Safety Standards. 11 and Pg. 7 kW) and include common 50 and 60 Hertz, single and three phase voltages. They dampen the start-up surge of the compressor and minimise sound and vibration transmission to the compressor base during operation. When you introduce customers to Copeland scroll compressors, you’re giving them the most advanced technology in the industry. Compressor Line-up Product Family – Residential and Light Commercial Emerson Climate Technologies provides a full-line of Copeland Scroll™ residential compressors that are: R Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. Copeland Stream 4M* and 6M* compressors are intended for installation in systems in accordance with the following directives and regulations: respect to the equivalent fixed capacity Copeland Scroll compressors. Share. 7. With Copeland certified compressors, you get 100 percent Nomenclature Compressor family series C Hermetic Reciprocating Refrigerant R R22,R134a,R407C Capacity XX First two digits of nominal capacity Btu/h @ 60 Hz K x 1,000 multiplier Product family variations 6,7,8 CR Q CR Large Id entifier M Optimized Design Oil type Compressor family Z = Copeland scroll Y = Copeland scroll, flammable refrigerants Capacity multiplier K = x 1000 M = x 10000 . An example would be discus copelametic® compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. It gives details on the compressor specifications, Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. An example would be the YA31K1E-PFV, which has 31,000 Btu/hr (9. 5 4. hub01@hubhvacr. comp. It is the most efficient and durable compressor Emerson Climate Technologies The 20 to 40 ton Copeland Scroll compressors do not have internal pressure relief valves. URL of this page: HTML Link: Bookmark You deserve to be as informed as possible about the products you purchase. 9 Copeland Variable Speed Solutions Reliability Integrated solutions Environmentally friendly refrigerants Energy efficiency 8 With an unparalleled commitment to engineering excellence, innovative design, Nomenclature The model designation contains the following technical information: The Copeland 4MTLS compressor model numbers with R-744 refrigerant include the nominal capacity at 60 Hertz using the standard operating conditions below: Evaporating temperature: 14°F (-10°C) SEPTEMBER 2024 BULLETIN AE4-1396 R10. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. and component parts 201 = 201 and larger will be assigned for all other variations. com. 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Also for: Copeland k series, Copeland l series, Copeland s series, Copeland 2d series, Copeland 3d series, Copeland 8d series, Copeland 6t series, Sign In Upload. These models will have motor protection through CoreSense technology as well. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Compressor family Z = Copeland scroll K = x 1000 M = x 10000 BOM indication. = Three-phase motor part-winding 2/3 - 1/3 Three-phase motor WA Volt 220 - 240 380 - 420 380 - 420 220 - 240 500 - 550 220 - 240 380 - 420 440 - 480 208 - compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. 00. These models include all of the standard 50 and 60 Hertz three phase voltages. Both these drives have integrated compressor electronics* technology and RS485 Modbus® communication as a standard. These compressors are designed to operate safely and reliably in the high, medium, and extended medium temperature ranges. These compressors are intended for installation in systems in accordance with the Machinery Directive MD 2006/42/EC. ZB Series Scroll Compressor. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. Copeland digit 2 compressor type a = standard air cooled d = discus refrigerant cooled r = standard refrigerant cooled t = two stage w = standard water cooled a digit in this position (e. The Condensing unit voltage range is various Discus nomenclature specifications. This results in significantly reduced efficiency and performance, as well as increased costs to your customers. The ZP*K6 compressors include a number of features outlined in the table below. Copeland semi-hermetic compressors are manufactured according to the latest relevant European safety standards. The series has a wide application envelope The 6-to-15-ton ZP*KZ Copeland Scroll compressors are designed for a variety of commercial air conditioning and chiller applications. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. 200 = std. 85 6D Floating Reed Models. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. It gives details on the compressor specifications, eg, compressor housing Copeland Discus compressors. Scroll Compression process 6-6 2. 1 ZB Series 2 HP 5 HP 10 HP 15 HP Emerson's range of ZB Series of scroll compressors ZB92KC~ZB11M ZB50KQ~ZB88KQ ZB30KQ~ZB45KQ ZB15KQ~ZB26KQ Copeland Corporation was established in 1921 in Detroit City, Michigan State, U. Copeland Scroll compressors are manufactured according to the latest European and US Safety Standards. Testing Guidelines 11-13 6. Electrical Hazards 4. The distance depends on the pressure and the amount of refrigerant and oil mixture in the system. 75 6. ZB Copeland Scroll compressor pdf manual download. They may be put to service only if they have been installed in these systems according to Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. ) installed on the compressor Further technical information can be found in the following documentation: Discus compressor application Guidelines D6. 98 MB Copeland™ ZP Scroll Compressor Range for R410A Copeland Discus Series air compressor pdf manual download. Replacements based on +/- 10% actual capacity Cross Reference Guide | 5 LG Scroll Compressor Cross Reference Model Cap (BTU) Model Cap (BTU) Volts RLA (MCC -1. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. a external inherent protection. 5 = 7. 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor project a significant distance from the compressor. You The centre letter of the motor code in the nomenclature of a Copeland Scroll™compressor indicates which kind of motor protection device is used. BULLETIN NO: AE4-1387 R11 . Copeland Scroll UltraTech compressor nomenclature Z P S 30 K 5 E – P F V –130 Z scroll family series AC, R-410A/B UltraTech operation of the air conditioner compressor. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low speed operation) to 7200 revolutions per minute and is intended for use in commercial air conditioning, chiller, and Check that the compressor is properly grounded per the applicable system and compressor requirements. 1°C), View and Download Emerson Copeland 4MF-13X user manual online. 4 Emerson developed the ZFKQ range of Copeland ScrollTM compressors to provide the best performance in low temperatures. 5 5 5. 2kW) cooling Most Common Regions. copeland™ service cr compressor cross reference guide single phase three phase tonnage cr6/5 ton bristol tecumseh carlyle danfoss zrk5/k3 3. This bulletin describes the operating characteristics, design Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. E Copeland Scroll™ Compressor Eliminates Issues at Meat Processing Facility: English, Français: PDF: 574 kB : Download: Supermarket Becomes More Eco-Friendly Using Copeland Scroll™ Compressors: English, Français: PDF: 177 kB: Download: Case Study - Unique Refrigeration System Leverages Copeland Digital Scroll Compressors: English: PDF: 500 kB: Download: Copeland™ hermetic compressors are dependable, cost-effective and versatile. No compression takes place We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Emerson Copeland 3D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. 3. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. 3 - 15. 2. In addition, some of the extended medium temperature compressors have the ability to operate in Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. 12x 8. 11 Oil Management drawing added Pg. 2/0901 Copeland Scroll AC Compressor Supplier in China, We Can Supply You with Copeland Scroll Heat Pump Compressor, Refrigeration Compressor, Freezer Compressor, etc. compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. units. Compressor Information 8-10 4. ' Product Description ZPV066 and ZPV096 variable speed compressors are intended for use in commercial air conditioning, chiller, and heat pump applications. com/OPI to determine its compressor model. 3 to 3 HP, R22, R134a, R404A 1/ 2 Split AC Cold Room Display Cabinet Water copeland-cf-and-cs-compressor-catalogue. compressors. 5 1 1. From this site, compressor drawings (PDF format) can be downloaded. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr Copeland Scroll compressor are described in Figure 1 of this bulletin. 1 Common information about Copeland Scroll compressors The Scroll compressor has been under development at Emerson Climate Technologies since 1979. Check that the compressor is properly grounded per the applicable system and compressor requirements. The cover or plug helps to Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. We Copeland Discus ™ compressors on 4D and 6D platforms starting in June 2012. Copeland 4MF-13X compressor pdf manual download. Also for: Copeland scroll zp kc series, Copeland scroll zr84kce-tf, Copeland Scroll compressor are described in Figure 9 at the end of this bulletin. 240 volt control. xx8 will identify units under 6A that are listed, but do not have pressure controls. 5”x7. The flames can cause serious or fatal burns and ignite nearby materials. Add Manual will be automatically added to "My DWM Copeland™ compressors are suitable for a wide range of applications either in the form of single compressors, condensing units or as multi-compressor equipment. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD 100 = std. Emerson leveraged its global resources and experience to enhance reliability and performance. two stage w water cooled primary application range r = ari high temp, rated @ 45/130 s = ari med temp, rated @ 20/120 f = ari low temp, rated @ -25/105 Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech ® T = Tandem (even) U = Uneven Tandem Nominal Capacity at Rating Condition Capacity Multiplier K = 1,000 M = 10,000 Model Variation 4, 5, C Oil type E = POE Oil = AK/ DA or 3MA P = Single Phase Motor T = Three Phase Motor F = Internal For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). 10 Oil and Refrigerant table added Pg. North America. com and select Online Product Information (OPI) or CopelandScroll. The scroll set is mounted at the upper end of the rotor shaft of the motor. 800 = std. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions Copeland Scroll™compressors are manufactured according to the latest U. scroll condensing units For medium and low temperature refrigeration applications. 3. Download Table of Contents Contents. Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Nomenclature The ZR*KC and ZP*KC model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. The ZP*KA family includes the features outlined in the matrix below. 1 – Energy Efficiency The Copeland Scroll Outdoor Refrigeration Unit signifi cantly reduces energy consumption by utilizing scroll compressor technology, variable speed fan motors, large Model Nomenclature & BOM Summary 45-45. 0 8. The Copeland Discus platform will continue to offer industry leading energy efficiency, digital modulation and CoreSense ™ technology. These compressors are intended for installation in systems in accordance with the European Machinery directive MD 2006/42/EC, the Pressure Equipment Directive PED 2014/68/EU and the Low Voltage Copeland hermetic compressors For medium temperature refrigeration applications A cost effective hermetic solution Copeland hermetic reciprocating compressors provide cost-effective solutions to systems requiring a wide range of evaporating capability. It gives indications on the compressor specifications in terms of compressor housing, variation and IP rating of the Copeland Compressor Nameplate Voltages BULLETIN NO: AE9-1228 R7 Safety Important Safety Information 2 Responsibilities, Qualifications and Training 2 Terminal Venting and Other Pressurized System Hazards 2 Flammable Refrigerant Hazards 3 Electrical Hazards 3 Hot Surface and Fire Hazards 3 Lifting Hazards 3 POE Oil Hazards 3 Precautions 3 Signal Word Refrigeration Copeland Compressors 1. Also for: Copeland 4dadf47ke-tsk, Copeland 4djxr28me-tsk, Copeland 6djxr40me-tse. g. 5t cr42k6-pfv h20j403abc ah40x15 j*42 mt040-1 zr42k5-pfv h20j423abc ah5540e j*45 h20j433abc ah5540f p*46 h20j443abc ah5540g py4666 h21a413 ah8548e h21a413abc av5540f h21j40babc av5542e h21j433abc av5542f h21j43babc Copeland Compressor body - Nr of cylinders 2 cylinders 3 cylinders 6 cylinders 8 c linders Compressor technology: D = Discus T = Two-stage Compressor version Stroke / Bore variation c Motor size 150 Motor type. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 1 Compressor Capacity Modulation for Air Conditioning & Refrigeration Systems 1. used in copeland cond. A. Field & Installation Guidelines 13-14 Performance Data 15-43 R22 50Hz 1-Phase 15-16 R22 50Hz 3 . 5x 9. 1 Capacity Control Compressors in the higher capacity range need some form of capacity control to accommodate varying refrigeration load. Sign In Upload. If a compressor’s electrical terminal pin loses its seal, pressurized oil, For more detailed information related to voltage ranges for CopelandTM condensing units look on Emerson. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp Multiple H M L Copeland Scroll Compressor for CO2 Subcritical Refrigeration (R-744) BULLETIN NO: AE4-1372 R7 Safety Important Safety Information 2 Responsibilities, Qualifications and Training 2 Terminal Venting and Other Pressurized System Hazards 2 Flammable Refrigerant Hazards 3 Electrical Hazards 3 Hot Surface and Fire Hazards 3 Lifting Hazards 3 Compressor Replacement After a Copeland Scroll compressor are described in Figure 1. System Protection Guidelines 10-11 5. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. Operating Envelope There are various refrigerants that have been approved for use with this family of compressors, see Table 2 at the end of this Copeland semi-hermetic compressors are manufactured according to the latest relevant European safety standards. 6/0218/E 2/8 2 BOM number The BOM (Bill Of Material) number contains three digits and can be found at the end of the scroll compressor nomenclature. Pg. 10 Crankcase kit table added Pg. Electrical Codes 60 Hz. information. Compressors with rotalock Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. S. 5 to 15 HP). 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. Value Copeland Discus With CoreSense Protection Basic Protection And Diagnostics - Oil & Standard Motor Protection Communication On Every Discus Copeland Discus With CoreSense Diagnostics Applied Cost Savings - Integration Of Traditional Accessories - Reduced Wiring - Reduced Assembly Labor View and Download Emerson COPELAND F Series user manual online. Whether designing for a roof-top unit in the United States or an air The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. 1. 12 - Nomenclature - Serial Number LG Service Compressor Kit Copeland Copeland. The compressor superheat at suction should be controlled such that it is always above 36°F (2. 2 Nomenclature The model designation contains the following technical information about the Copeland Scroll™ variable speed compressor in a safe and reliable manner. 7 kW) and 90,000 to 182,000 Btu/hr (26. The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard Copeland Scroll™ UltraTech™ ZPSK5 R-410A Service Compressor Specification Chart Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Rotalock™ Kit Part Numbers The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 ordering compressor with water coil. See Figure 3. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 3 kW) respectively. 12 Mounting parts drawings added. 50 Hz. For more than 80 years, it has been our endeavour to bring cutting-edge products to Copeland Discus with CoreSense Technology Provides Higher Value . Safety Instructions Copeland Scroll™ compressors are manufactured according to the latest U. The metal sleeve inside is a guide designed to hold the Nomenclature : 5 : Bill of material : 5 : Operating envelopes : 6 : Product line-up : 8 : Performance data : 9 : Technical data : 46 : Dimensional drawings : 49 : Electrical wiring diagram : 64 : Quick application guide : 66 : Available models list : 76 : Contact list : 79 : Copeland is the world’s leading compressor manufacturer and is committed to maximizing system effciency and The centre letter of the motor code in the nomenclature of a Copeland Scroll™compressor indicates which kind of motor protection device is used. Please see Figure 3 and Operating principles of the Copeland Scroll compressor are described in Figure 7. 5 4 4. pdf - Free download as PDF File (. The centre letter "F" (eg, TFD) stands for inherent motor protector (Klixon) which is embedded in the stator head and interrupts the power supply of the windings internally at high current or high Nomenclature 7 Operating Envelope Figure 1 ZB**KAE and YB**KAE R7 Application Considerations Accumulators 7 Superheat Requirements 7 Crankcase Heaters 8 Discharge Line Thermostat 8 Pressure Controls 8 Pump Down Recommendations 8 IPR Valve 8 Internal Temperature Protection 8 Motor Protection 9 Oil Types 9 Oil Charges 9 Compressor Tubing Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. BULLETIN NO: AE4-1481 R1 ; Safety; Important Safety Information 3 Responsibilities, Qualifications and Training 3 Terminal Venting and Other Pressurized System Hazards 3 Flammable Refrigerant Hazards 4 Electrical Hazards 4 Hot Surface and Fire Hazards 4 Lifting Hazards 4 POE Oil Hazards 4 Precautions 4 Signal - Copeland Stream Compressors with CoreSense Diagnostics for R744-Transcritical Applications - Copeland Stream Compressors with CoreSense Diagnostics for R744-Subcritical Applications - Service Compressors for 4 and 6 Cylinder S-Series and Discus Reciprocating Compressors Refrigeration Units - Copeland EazyCool™ Outdoor Refrigeration Units with Scroll 1 2015 Emerson Climate Technologies, Inc. Also for: Copeland scroll zb15, Copeland scroll zb29, Copeland scroll zb38, Copeland scroll zb48, Copeland scroll zb58, Copeland scroll Sign In Upload. 95 6D Capacity Control Kits . indd 1 2/29/2016 9:42:57 AM. 4DH3R22ML-TSK-C00. 5kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. United States English 100 = std. txt) or read online for free. ohkglb vsdbxm ljnb yuvhe ehbx qyyhsy ieiueekw bnblb vgm icg